Ceiling Air Conditioner GENERAL FUJITSU ABHG54LRTA / AOHG54LATT

5,393.62

Product total
Options total
Grand total
ManufacturerGENERAL FUJITSU
For roomsover 100 m²
Recommended volume (cooling)300 m³
Recommended volume (heating)260 m³
Output power (cooling)5.40 – 14.00 – 16.00 kW
Output power (heating)5.80 – 16.00 – 18.00 kW
Power consumption (cooling)4.65 kW
Power consumption (heating)4.67 kW
Power supply380 - 415 V~ 50 Hz, 3 Ph
Noise level (indoor unit)38 dB
Noise (outdoor unit)55 dB
Dimensions W x H x D (indoor unit)1660 x 240 x 700 mm
Dimensions W x H x D (outdoor unit)900 x 1290 x 330 mm
Weight (indoor unit)84 kg
Weight (outdoor unit)104 kg
Pipe connections (liquid/gas)ø 10 mm / ø 16 mm
Operating temperature range cooling (°C)-15 °C to +46 °C
Operating temperature range heating (°C)-15 °C to +24 °C
RefrigerantR410A
OriginChina
10°C Heat

The room temperature can be maintained at no more than 10°C, ensuring the room does not cool down when not in use.

ALL DC models

High-efficiency DC inverter processor, allowing for higher energy efficiency compared to conventional compressors.

V-PAM controlled models

Reduces magnetic flux effects and increases maximum compressor speed and efficiency using vector control technology.

Auto restart

In the event of a temporary power failure, the air conditioner will automatically restart in the previous mode once power is restored.

Auto fan speed

A microcomputer automatically adjusts the airflow to effectively follow changes in room temperature.

Auto changeover

The system automatically switches between heating and cooling modes based on the set temperature and room temperature.

Automatic setpoint reset

The set temperature automatically returns to the previously set temperature.

Auto double swing

The complex swing function of the flaps allows them to move automatically in both horizontal and vertical directions.

Fresh air intake

Fresh air can be drawn in via a fan connected using an external control board.

External ON/OFF input
Drain pump
Economy mode

Thermostat settings automatically change based on temperature to avoid unnecessary cooling or heating.

Set temperature limit

Minimum and maximum temperature ranges can be set to provide additional energy savings while maintaining occupant comfort.

Fresh air duct connection

Outdoor air can be introduced by connecting an optional fresh air duct.

Weekly timer

Different ON/OFF times can be set for each day.

Auto-off timer

Automatically stops operation after a fixed time from the start has elapsed.

Sleep timer

The microcomputer gradually changes the room temperature automatically to ensure a comfortable night's sleep.

Program timer

This digital timer allows selection of one of four options: ON, OFF, ON » OFF, or OFF « ON.

Low noise mode

Outdoor unit noise levels can be selected.

Filter indicator

A lamp indicates when the filter needs cleaning.